Standards

Office Lighting Specifications: Using EN 12464-1

Prepare an office-lighting brief covering task illuminance, glare, uniformity, color quality, daylight, and the evidence needed to review a layout.

2 min read
·
Aug 7, 2026
·
By Wei Zhang, Lighting Engineer
modern office corridor with recessed ceiling lights and black pendant fixtures

An office specification needs more than a panel marked “500 lux” or “UGR <19.” Light levels and glare are properties of the installation, so review the fixture within the actual room layout.

Identify the tasks and reference criteria

EN 12464-1 addresses lighting of indoor workplaces. Confirm the edition and requirements used by the project, then identify reading, screen work, circulation, meeting areas, and any specialist tasks.

State the working plane and maintained target

A target such as 500 lux is meaningful only with a defined task area, working plane, maintenance factor, and surrounding-area criteria. Record these in the design brief and calculation report.

Review glare from occupied positions

A tabulated UGR value uses reference conditions. Check the actual room dimensions, surface reflectances, fixture spacing, and viewing directions. Review reflections on screens as part of the sample installation.

Check uniformity and color quality

Compare the minimum and average light levels, not just the average. Specify CCT and color tolerance across the installation. Use the required color-rendering criteria and sample review where finishes or skin tones are important.

Coordinate controls with the design

Define daylight zones, occupancy detection, manual overrides, and after-hours use. Check the building requirements that apply locally. Controls should maintain the agreed task conditions while reducing unnecessary operating hours.

Request a reproducible layout

Ask for the fixture file, dimensions, mounting height, reflectances, maintenance assumptions, calculation grid, and control schedule. Measure the completed installation and keep the results with the handover record.

Frequently Asked Questions

Does UGR <19 on a datasheet guarantee the office result?

No. The glare result depends on the room, layout, and viewing directions used in the assessment.

Can I use one light level throughout an office?

Different tasks and surrounding areas may have different requirements. Prepare the brief by activity and location.

Browse lighting guides · Request product specifications

Share this article:

Wei Zhang

Lighting Engineer at Tonghua Lighting

Wei Zhang is a senior lighting engineer with over 10 years of experience in LED lighting design and manufacturing. He specializes in photometric analysis, IES-standard compliance, and B2B lighting solutions for commercial and industrial applications.

Related Articles

A practical next step

Have a project behind this question?

Send the models you are considering, quantities, finish, and destination. We can help check the specification and prepare a quote.

WhatsApp Enquire Products